Author:admin 2019-07-02
The vulnerable parts of diesel generator set include air filter, oil filter and fuel filter. In order to extend the service life of diesel generator set, it is necessary to strengthen the maintenance of air filter, oil filter and fuel filter to give full play to their role. Air filter in the installation of leakage, reverse or wrong installation of each sealing gasket and rubber connection pipe, and to ensure the tightness of each embedded. Paper dust cup air filter used, every 50-100 hours of work, to clear dust once, can brush the surface dust brush, if the working time is more than 500 hours or damaged, should be replaced in time. Use oil-bath air filter. Clean the filter element with clean diesel oil every 100-200 hours and change the oil. If the filter element is broken, change it immediately.